Description
The NEW Fluke 77-4 digital multimeter includes features required to fix nearly all electronic and electrical problems. This multimeter is has significant improves over the original, is extremely easy to use, conforms to the latest safety standards, and includes a much larger display that is much easier to view.
Features and Benefits:
- Large display.
- Backlight for work in dim areas.
- Min / Max to record signal fluctuations.
- Ergonomic overmolded housing with probe holders.
- Optional TPAK magnetic hander frees your hands.
- Auto and Manual Ranging Capabilities.
- Meets measurement category 1000 V CAT III and Category IV 600 V safety standards.
It measures:
- Wide 1000 V measurement range.
- Average responding AC measurements.
- 0.3% accuracy.
- 10 Amps continuous (20A for 30 seconds).
- Capacitance and Frequency.
- Continuity and Resistance.
Multimeter includes a limited lifetime warranty, test leads, manual and battery.
| Detailed Specifications |
| Voltage DC |
| Range: |
6.000V - 1000V |
| Best Accuracy: |
+/- (0.3% + 1) |
| Best Resolution: |
0.1 mV |
|
| Voltage AC |
| Range: |
600.0 mV-1000V |
| Best Accuracy: |
+/- (2.0% + 2) |
| Best Resolution: |
1.0 mV |
|
| Amps AC |
| Range: |
60.00 mA – 10A |
| Best Accuracy: |
+/- (1.5% + 2) |
| Best Resolution: |
0.01mA |
|
| Amps DC |
| Range: |
60.00 mA – 10A |
| Best Accuracy: |
+/- (2.5% + 2) |
| Best Resolution: |
0.01 mA |
|
| Resistance |
| Range: |
600.0 Ω - 50 MΩ |
| Best Accuracy: |
+/- (0.5% + 1) |
| Best Resolution: |
0.1Ω |
|
| Capacitance |
| Range: |
1nF- 9,999 µF |
| Best Accuracy: |
+/- (1.2% + 2) |
| Best Resolution: |
1 nF |
|
| Frequency |
| Range: |
99.99Hz- 99.99kHz |
| Best Accuracy: |
+/- (0.1% + 1) |
| Best Resolution: |
0.01Hz |
|
| Safety |
| |
ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV |
|
| Certifications |
| |
CSA, TÜV (EN61010), UL, Π, ; (N10140),VDE |
|
| General Specifications |
| Maximum voltage between any terminal and earth ground |
|
| Surge protection |
|
| Ω Fuse for mA inputs |
|
| Ω Fuse for A inputs |
|
| Display |
| Digital: |
6000 counts, updates 4/sec |
| Bar Graph: |
33 segments; Updates 32/sec |
| Frequency: |
10,000 counts |
| Capacitance: |
1,000 counts |
|
| Altitude |
| Operating: |
2,000 meters |
| Storage: |
12,000 meters |
|
| Temperature |
| Operating: |
-10 °C to +50 °C |
| Storage: |
-40 °C to +60 °C |
|
| Temperature Coefficient |
| |
0.1 X (specified accuracy / °C (< 18 °C or > 28 °C) |
|
| Electromagnetic Compatibility (EN 61326-1:1997) |
| |
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F) |
|
| Relative Humidity (Maximum Non-condensing) |
| |
90 % to 35 °C |
| |
75 % to 40 °C |
| |
45 % to 50 °C |
|
| Battery Life |
| |
400 Hours Typical (Alkaline) |
|
| Size |
| Height: |
4.3 cm |
| Width: |
9 cm |
| Length: |
18.5 cm |
|
| Weight |
|
Knowledge and Information