Description
From the plant floor to the control room, the Fluke 87 digital multimeter has earned it's place one of the most trusted multimeters by technicians. When it comes to productivity and speed, the Fluke 87V Series Multimeter delivers the advanced troubleshooting and accuracy that you need to solve electrical problems quickly.
The Fluke 87V True-RMS Multimeter includes a low pass filter to measure frequency and voltage accurately on noisy electrical equipment similar to adjustable motor drives. The peak capture function can easily detect intermittent problems and transients as fast as 250 micro seconds.
You can now work with confidence. The Input Alert feature provides you with an audible warning against the use of input jacks. The Fluke 87V True RMS digital multimeter is tested for use in CAT IV 600V/CAT III 1000V environments. They reduce risk related to surges and spikes, and can withstand impulses of more than 8,000 V.
Fluke takes ideas directly from the job site and puts them in their products. They work with users like you to create tools that do the job quickly, effectively, and as long as you need it. Fluke designs and builds the Fluke 87V right here in the United States and back them by a Limited Lifetime Warranty. Work smarter, safer, and faster with a Fluke 87V today.
Features and Benefits:
- Built-in thermometer allows you to carry only one instrument when taking temperature readings.
- Automatic and Manual ranging for maximum flexibility
- Unique function for accurate frequency and voltage measurements on noisy electronic equipment.
- Measure up to 1000V AC and DC.
- Large digital display, 6000 counts, 3-3/4-digits. Two level backlight, extremely easy to read.
- Optional magnetic hanger for easy set up and viewing while freeing your hands.
| Specifications |
| Voltage DC |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 83 V: ±(0.1%+1) |
| |
Fluke 87 V: ±(0.05%+1) |
| Maximum Resolution: |
Fluke 83 V: 100 µV |
| |
Fluke 87 V: 10 µV |
|
| Voltage AC |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 83 V: ±(0.5%+2) |
| |
Fluke 87 V: ±(0.7%+2) True RMS |
| AC Bandwidth |
Fluke 83 V: 5kHz |
| |
Fluke 87 V: 20kHz* |
| |
*with low pass filter; 3db @ 1kHz |
| Maximum Resolution: |
0.1 mV |
|
| Current DC |
| Maximum Amps: |
10A (20 A for 30 seconds maximum) |
| Amps Accuracy: |
Fluke 83 V: ±(0.4%+2) |
| |
Fluke 87 V: ±(0.2%+2) |
| Maximum Resolution: |
Fluke 83 V: 0.01 mA |
| |
Fluke 87 V: 0.01 µA |
|
| Current AC |
| Maximum Amps: |
10A (20 A for 30 seconds maximum) |
| Amps Accuracy: |
Fluke 83 V: ±(1.2%+2) |
| |
Fluke 87 V: ±(1.0%+2) True RMS |
| Maximum Resolution: |
0.1 µA |
|
| Resistance |
| Maximum Resistance: |
50 MΩ |
| Accuracy: |
Fluke 83 V: ±(0.4%+1) |
| |
Fluke 87 V: ±(0.2%+1) |
| Maximum Resolution: |
0.1Ω |
|
| Capacitance |
| Maximum Capacitance |
9,999 µF |
| Accuracy |
±(1%+2) |
| Maximum Resolution |
0.01 nF |
|
| Frequency |
| Maximum Frequency |
200 kHz |
| Accuracy |
±(0.005%+1) |
| Maximum Resolution |
0.01 Hz |
|
| Duty Cycle |
| Maximum Duty Cycle |
99.9% |
| Accuracy |
±(0.2% per khz +0.1%) |
| Maximum Resolution |
0.1% |
|
| Temperature Measurement |
| Fluke 87 V, 87 V/E: |
-200.0°C - 1090°C |
| |
-328.0°F - 1994.0°F |
| |
excluding probe |
|
| 80 BK Temperature Probe |
| |
-40.0°C - 260°C |
| |
-40.0°F - 500°F, 2.2°C or 2% whichever is greater |
|
| Conductance |
| Maximum Conductance |
60.00 nS |
| Accuracy |
±(1.0%+10) |
| Maximum Resolution |
0.01 nS |
|
| Diode |
| Range: |
3 V |
| Resolution: |
1 mV |
| Accuracy: |
± (2 % + 1) |
|
| Duty Cycle Range |
| Accuracy: |
Within ± (0.2% per kHz + 0.1 %) |
|
| Environmental Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Humidity (Without Condensation) |
| |
0% - 90% (0°C - 35°C) |
| |
0% - 70% (35°C - 55°C) |
|
| Operating Altitude |
|
| Safety Specifications |
| Overvoltage category |
| |
EN 61010-1 to 1000 V CAT III, 600V CAT IV |
|
| Agency Approvals |
|
| Mechanical & General Specifications |
| Size |
| |
201 x 98 x 52 mm (with holster) |
|
| Weight |
|
| Weigh With Holster and Flex-Stand |
|
| Display |
| Digital: |
6000 counts updates 4/sec. |
| |
(Model 87 also has 19,999 counts in high-resolution mode.) |
| Analog: |
32 segments, updates 40/sec. |
| Frequency: |
19,999 counts, updates 3/sec at > 10 Hz. |
|
| Warranty |
|
| Battery Life |
| Alkaline: |
~400 hours typical, without backlight |
|
| Shock |
| |
1 Meter drop per IEC 61010-1:2001 |
|
| Vibration |
| |
Per MIL-PRF-28800 for a Class 2 instrument |
|
Knowledge and Information