Description
For professional technicians all over the world, there is one preferred solution: the reliability, easy, and precision of a Fluke 177 True RMS Digital Multimeter. The Fluke 177 is the industry standard, and can help you repair and troubleshoot nearly any problem in electronic systems and electrical.
Fluke 177 Digital Multimeters give you 6000-count resolution, automatic ranging (provides frequency), True RMS voltage, continuity, diode measurements, capacitance, and resistance. In addition, the Fluke Series 177 provides higher 0.09% basic accuracy, analog bar graph, digital display and backlight.
Features and Benefits:
- 0.09% Basic Accuracy.
- True RMS current and voltage measurements.
- Manual and automatic range.
- Capacitance, frequency, and continuity measurements.
- Digital display with analog bargraph and backlight.
Other features include: Min-max-average recording, display hold and auto hold, smoothing mode allows filtering of rapidly changing inputs, ergonomic case with holster, closed case calibration through front panel, easy battery exchange without opening the case.
| Detailed Specifications |
| Voltage DC |
| |
|
| 177 - Accuracy* |
± (0.09%+2) |
| Max. Resolution |
0.1 mV |
| Maximum |
1000 V |
|
| Voltage AC |
| Accuracy* |
± (1.0%+3) |
| Max. Resolution |
0.1 mV |
| Maximum |
1000 V |
|
| Current DC |
| Accuracy* |
± (1.0%+3) |
| Max. Resolution |
0.01 mA |
| Maximum |
10 A |
|
| Current AC |
| Accuracy* |
± (1.5%+3) |
| Max. Resolution |
0.01 mA |
| Maximum |
10 A |
|
| Resistance |
| Accuracy* |
± (0.9%+1) |
| Max. Resolution |
0.1 Ω |
| Maximum |
50 MΩ |
|
| Capacitance |
| Accuracy* |
± (1.2%+2) |
| Max. Resolution |
1 nF |
| Maximum |
10,000 µF |
|
| Frequency |
| Accuracy* |
± (0.1%+1) |
| Max. Resolution |
0.01 Hz |
| Maximum |
100 kHz |
|
| Temperature |
| 177 - Accuracy* |
± (0.09%+2) |
| Max. Resolution |
0.1°C |
| Range |
-40°C/400°C |
|
| Note |
| * |
Accuracies are best accuracies for each function |
|
| Environmental Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Humidity (Without Condensation) |
| |
0% - 90% (0°C - 35°C) |
| |
0% - 70% (35°C -50°C) |
|
| Safety Specifications |
| Overvoltage category |
| |
EN 61010-1 to 1000 V CAT III. |
| |
EN 61010-1 to 600 V CAT IV. |
|
| Agency Approvals |
| |
UL, CSA, TÜV listed and VDE Pending |
|
| Mechanical & General Specifications |
| Size |
|
| Weight |
|
| Warranty |
|
| Battery Life |
| Alkaline: |
~200 hours typical, without backlight |
|
Safety Conformance
Fluke 177 multimeters are independently tested for safe use in CAT IV 600V/CAT III 1000V environments.
Knowledge and Information