Description
The Fluke 83V has a wide variety of features that make it widely known as the "Insductrial Standard" when it comes to multimeters.
The Fluke 83-5 features peak capture to record transients as fast as 250µs, auto and manual ranging for maximum flexibility, analog bar graph for fast changing or unstable signals, relative test mode to remove test lead interference from low ohms measurements, large display with a two-level bright white backlight display for increase visibility, and audible input alerts warning against wrong use of input jacks.
In Addition, the Fluke 83V Also Features:
- 6000 counts, 3-3/4-digits.
- Measures up to 1000V AC and DC.
- Min/Max-Average recording with Min/Max to capture variations automatically.
- Analog bar graph for fast changing or unstable signals.
- Improved selectable sleep mode for long battery life.
- Measure up to 10 A, 20 A, for up to 30 seconds.
- Access door for fast battery changes without breaking the calibration seal.
- "Classic" design with new removable holster that includes built in probe and test lead storage.
| Detailed Specifications |
| Voltage DC |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 83 V: ±(0.1%+1) |
| |
Fluke 87 V: ±(0.05%+1) |
| Maximum Resolution: |
Fluke 83 V: 100 µV |
| |
Fluke 87 V: 10 µV |
|
| Voltage AC |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 83 V: ±(0.5%+2) |
| |
Fluke 87 V: ±(0.7%+2) True RMS |
| AC Bandwidth |
Fluke 83 V: 5kHz |
| |
Fluke 87 V: 20kHz* |
| |
*with low pass filter; 3db @ 1kHz |
| Maximum Resolution: |
0.1 mV |
|
| Current DC |
| Maximum Amps: |
10A (20 A for 30 seconds maximum) |
| Amps Accuracy: |
Fluke 83 V: ±(0.4%+2) |
| |
Fluke 87 V: ±(0.2%+2) |
| Maximum Resolution: |
Fluke 83 V: 0.01 mA |
| |
Fluke 87 V: 0.01 µA |
|
| Current AC |
| Maximum Amps: |
10A (20 A for 30 seconds maximum) |
| Amps Accuracy: |
Fluke 83 V: ±(1.2%+2) |
| |
Fluke 87 V: ±(1.0%+2) True RMS |
| Maximum Resolution: |
0.1 µA |
|
| Resistance |
| Maximum Resistance: |
50 MΩ |
| Accuracy: |
Fluke 83 V: ±(0.4%+1) |
| |
Fluke 87 V: ±(0.2%+1) |
| Maximum Resolution: |
0.1Ω |
|
| Capacitance |
| Maximum Capacitance |
9,999 µF |
| Accuracy |
±(1%+2) |
| Maximum Resolution |
0.01 nF |
|
| Frequency |
| Maximum Frequency |
200 kHz |
| Accuracy |
±(0.005%+1) |
| Maximum Resolution |
0.01 Hz |
|
| Duty Cycle |
| Maximum Duty Cycle |
99.9% |
| Accuracy |
±(0.2% per khz +0.1%) |
| Maximum Resolution |
0.1% |
|
| Temperature Measurement |
| Fluke 87 V, 87 V/E: |
-200.0°C - 1090°C |
| |
-328.0°F - 1994.0°F |
| |
excluding probe |
|
| 80 BK Temperature Probe |
| |
-40.0°C - 260°C |
| |
-40.0°F - 500°F, 2.2°C or 2% whichever is greater |
|
| Conductance |
| Maximum Conductance |
60.00 nS |
| Accuracy |
±(1.0%+10) |
| Maximum Resolution |
0.01 nS |
|
| Diode |
| Range: |
3 V |
| Resolution: |
1 mV |
| Accuracy: |
± (2 % + 1) |
|
| Duty Cycle Range |
| Accuracy: |
Within ± (0.2% per kHz + 0.1 %) |
|
| Environmental Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Humidity (Without Condensation) |
| |
0% - 90% (0°C - 35°C) |
| |
0% - 70% (35°C - 55°C) |
|
| Operating Altitude |
|
| Safety Specifications |
| Overvoltage category |
| |
EN 61010-1 to 1000 V CAT III, 600V CAT IV |
|
| Agency Approvals |
|
| Mechanical & General Specifications |
| Size |
| |
201 x 98 x 52 mm (with holster) |
|
| Weight |
|
| Weigh With Holster and Flex-Stand |
|
| Display |
| Digital: |
6000 counts updates 4/sec. |
| |
(Model 87 also has 19,999 counts in high-resolution mode.) |
| Analog: |
32 segments, updates 40/sec. |
| Frequency: |
19,999 counts, updates 3/sec at > 10 Hz. |
|
| Warranty |
|
| Battery Life |
| Alkaline: |
~400 hours typical, without backlight |
|
| Shock |
| |
1 Meter drop per IEC 61010-1:2001 |
|
| Vibration |
| |
Per MIL-PRF-28800 for a Class 2 instrument |
|