Description
The Fluke 1587 Hybrid Insulation Tester & Multimeter provides the needed versatility when preventative maintenance and or trouble shooting is required. This compact, hand held device comes with an insulation tester (1 Kv) and a true-rms digital multimeter. And just as you would expect from any of the multimeters made by Fluke, the 1587 is extremely durable, highly reliable, and is very easy to use.
This digital multimeter is great for working on many different electrical machines and devices, such as motors (both gas and electric), generators, switch gear, cables, and much more. Comes with a remote probe, test leads, alligator clips, K-type thermocouple, AA batteries (4), and a quick reference guide + manual (on CD-ROM), and a hard carry case. The Fluke 1587 digital multimeter / insulation tester comes with everything that you need to get the job done.
Features
- Live circuit detection safety feature (automatically prevents insulation test if voltage greater than 30V is detected)
- Auto-discharge of capacitive voltage (for extra user protection)
- AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance, Continuity
- Testing for capacitance, diode, temperature, Min/Max and frequency
Specifications
- Hybrid Multimeter / Insulation Tester
- Display Type: Digital
- Size Generic: Standard
- Number of Test Ranges: 8 Ranges
- Insulation Test Voltages: 50V, 100V, 250V, 500V, 1000V
Included Accessories
- Remote Probe
- Test Leads
- Alligator Clips
- K-type thermocouple
- Batteries (4x AA)
- Quick Reference Guide
- Manual (On CD-ROM Disc)
- Hard Carry Case
| Detailed Specifications |
| Voltage DC |
| Maximum Voltage: |
1000 V |
| Accuracy: |
1577: ±(0.2%+2) |
| |
1587: ±(0.09%+2) |
| Maximum Resolution: |
0.001V |
|
| Voltage AC |
| Maximum Voltage: |
1000 V |
| Accuracy: |
1577: ±(2%+3) |
| |
1587: ±(2%+3) |
| AC Bandwidth: |
1587: 5kHz* |
| |
*with low pass filter; 3db @ 800 Hz |
| Maximum Resolution: |
0.1 mV |
|
| Current DC |
| Maximum Amps: |
400mA |
| Amps Accuracy: |
1577: ±(1.0%+2) |
| |
1587: ±(0.2%+2) |
| Maximum Resolution: |
0.01 mA |
|
| Current AC |
| Maximum Amps: |
400mA |
| Amps Accuracy: |
1577: ±(2.0%+2)* |
| |
1587: ±(1.5%+2)* |
| |
* 1kHz bandwidth |
| Maximum Resolution: |
0.01 mA |
|
| Resistance |
| Maximum Resistance: |
50 MΩ |
| Accuracy: |
1577: ±(1.2%+2) |
| |
1587: ±(0.9%+2) |
| Maximum Resolution: |
0.1Ω |
|
| Capacitance(1587 only) |
| Maximum Capacitance: |
9,999 µF |
| Accuracy: |
±(1.2%+2) |
| Maximum Resolution: |
1 nF |
|
| Frequency (1587 only) |
| Maximum Frequency: |
100 kHz |
| Accuracy: |
±(0.1%+1) |
| Maximum Resolution: |
0.01 Hz |
|
| Temperature Measurement (1587 only) |
| |
-40.0 °C to 537 °C |
| |
-40.0 °F to 998 °F |
| |
excluding probe |
|
| Diode Test (1587 only) |
| Range: |
6 V |
| Resolution: |
1 mV |
| Accuracy: |
±(2 % + 1) |
|
| Insulation Test |
| Minimum Test Current @ 1kΩ/V: |
|
| Test Voltages: |
| 1577: |
500, 1000 V |
| 1587: |
50, 100, 250, 500, 1000 V |
|
| Maximum Resistance per Test Voltage: |
| 50V: |
|
| 100V: |
|
| 250V: |
|
| 500V: |
|
| 1000V: |
1577: 600 MΩ |
| |
1587: 2 GΩ |
|
| Maximum Resolution per Test Voltage: |
| 50V: |
0.01 MΩ |
| 100V: |
0.01 MΩ |
| 250V: |
0.1 MΩ |
| 500V: |
0.1 MΩ |
| 1000V: |
0.1 MΩ |
|
| Accuracy per Test Voltage: |
| 50V: |
±(3 % + 5) |
| 100V: |
±(3 % + 5) |
| 250V: |
±(1.5 % + 5) |
| 500V: |
1577: ±(2.0 % + 5) |
| |
1587: ±(1.5 % + 5) |
| 1000V: |
1577: ±(2.0 % + 5) |
| |
1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ |
|
| Environmental Specifications |
| Operating temperature |
|
| Storage temperature |
|
| Humidity (Without Condensation) |
| |
0% - 95% (10 °C – 30 °C) |
| |
0% - 75% (30 °C – 40 °C) |
| |
0% - 40% (40 °C – 55 °C) |
|
| Operating Altitude |
|
| Safety Specifications |
| Overvoltage category |
| |
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
|
| Agency Approvals |
| |
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
|
| Mechanical & General Specifications |
| Size |
| |
203 x 100 x 50 mm (with holster) |
|
| Weight |
|
| Warranty |
|
| Battery life Alkaline |
| Meter use: |
1000 hours |
| Insulation test use: |
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
|
| IP Rating |
|
|
|
|