Fluke 1587 Hybrid Insulation Tester & Multimeter 

Item # FLU1587
List Price: $809.95
Sale Price: $618.42
Your savings: 24% ($191.53)
Customer Rating
(0 Ratings)
Availability:
In Stock
       QTY:          

Description

The Fluke 1587 Hybrid Insulation Tester & Multimeter provides the needed versatility when preventative maintenance and or trouble shooting is required. This compact, hand held device comes with an insulation tester (1 Kv) and a true-rms digital multimeter. And just as you would expect from any of the multimeters made by Fluke, the 1587 is extremely durable, highly reliable, and is very easy to use.

This digital multimeter is great for working on many different electrical machines and devices, such as motors (both gas and electric), generators, switch gear, cables, and much more. Comes with a remote probe, test leads, alligator clips, K-type thermocouple, AA batteries (4), and a quick reference guide + manual (on CD-ROM), and a hard carry case. The Fluke 1587 digital multimeter / insulation tester comes with everything that you need to get the job done.

 

Features

  • Live circuit detection safety feature (automatically prevents insulation test if voltage greater than 30V is detected)
  • Auto-discharge of capacitive voltage (for extra user protection)
  • AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance, Continuity
  • Testing for capacitance, diode, temperature, Min/Max and frequency

 

Specifications
  • Hybrid Multimeter / Insulation Tester
  • Display Type: Digital
  • Size Generic: Standard
  • Number of Test Ranges: 8 Ranges
  • Insulation Test Voltages: 50V, 100V, 250V, 500V, 1000V

Included Accessories
  • Remote Probe
  • Test Leads
  • Alligator Clips
  • K-type thermocouple
  • Batteries (4x AA)
  • Quick Reference Guide
  • Manual (On CD-ROM Disc)
  • Hard Carry Case
Detailed Specifications
Voltage DC
Maximum Voltage:  1000 V
Accuracy:  1577: ±(0.2%+2)
   1587: ±(0.09%+2)
Maximum Resolution:  0.001V
Voltage AC
Maximum Voltage:  1000 V
Accuracy:  1577: ±(2%+3)
   1587: ±(2%+3)
AC Bandwidth:  1587: 5kHz*
   *with low pass filter; 3db @ 800 Hz
Maximum Resolution:  0.1 mV
Current DC
Maximum Amps:  400mA
Amps Accuracy:  1577: ±(1.0%+2)
   1587: ±(0.2%+2)
Maximum Resolution:  0.01 mA
Current AC
Maximum Amps:  400mA
Amps Accuracy:  1577: ±(2.0%+2)*
   1587: ±(1.5%+2)*
   * 1kHz bandwidth
Maximum Resolution:  0.01 mA
Resistance
Maximum Resistance:  50 MΩ
Accuracy:  1577: ±(1.2%+2)
   1587: ±(0.9%+2)
Maximum Resolution:  0.1Ω
Capacitance(1587 only)
Maximum Capacitance:  9,999 µF
Accuracy:  ±(1.2%+2)
Maximum Resolution:  1 nF
Frequency (1587 only)
Maximum Frequency:  100 kHz
Accuracy:  ±(0.1%+1)
Maximum Resolution:  0.01 Hz
Temperature Measurement (1587 only)
   -40.0 °C to 537 °C
   -40.0 °F to 998 °F
   excluding probe
Diode Test (1587 only)
Range:  6 V
Resolution:  1 mV
Accuracy:  ±(2 % + 1)
Insulation Test
Minimum Test Current @ 1kΩ/V:
   1mA
Test Voltages:
1577:  500, 1000 V
1587:  50, 100, 250, 500, 1000 V
Maximum Resistance per Test Voltage:
50V:  
100V:  
250V:  
500V:  
1000V:  1577: 600 MΩ
   1587: 2 GΩ
Maximum Resolution per Test Voltage:
50V:  0.01 MΩ
100V:  0.01 MΩ
250V:  0.1 MΩ
500V:  0.1 MΩ
1000V:  0.1 MΩ
Accuracy per Test Voltage:
50V:  ±(3 % + 5)
100V:  ±(3 % + 5)
250V:  ±(1.5 % + 5)
500V:  1577: ±(2.0 % + 5)
   1587: ±(1.5 % + 5)
1000V:  1577: ±(2.0 % + 5)
   1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ
Environmental Specifications
Operating temperature
   –20 °C to +55 °C
Storage temperature
   -40°C to +60°C
Humidity (Without Condensation)
   0% - 95% (10 °C – 30 °C)
   0% - 75% (30 °C – 40 °C)
   0% - 40% (40 °C – 55 °C)
Operating Altitude
   2000 m
Safety Specifications
Overvoltage category
   Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency Approvals
   2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical & General Specifications
Size
   203 x 100 x 50 mm (with holster)
Weight
   624 g
Warranty
   3 years
Battery life Alkaline
Meter use:  1000 hours
Insulation test use:  Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating
   IP40

Knowledge and Information

Reviews

Summary Of Reviews: Fluke 1587 Hybrid Insulation Tester & Multimeter
Avg. Customer Rating:
 
 (based on 0 Reviews)
Be the first to Write A Review on the Fluke 1587 Hybrid Insulation Tester & Multimeter